Automated Ultrasonics
Hydrogen Induced Cracking
|
The images show "C Scan" and
"B Scan" plots of a sample containing Wet
Hydrogen damage. The techniques used to produce this form of data require the production of a consolidated data set. The data from transducers using multiple modes of ultrasound are used in a single array. The data from the multiple transducers is collected simultaneously, consolidated and shown as a single plot. |
|
Note, at a single location the sound is transmitted through the complete section of the sample. |
![]()
Case Study
| Sample | 0° Straight Beam & 45° Shear wave | Application | 96” ID Amine Flash Tank |
| Scan Date | July 2000 | Failure Mechanism | Wet H2S/HIC |
| Material | C-Steel, SA-516-70, 1.00” thickness | Customer | Gas Plant in Wyoming |
![]()
Last updated:
September 06, 2002Home AE Tank Technical Papers Conventions Email