Location of AE Sources
Location of AE sources in tanks is very hit and
miss.  Multipath (reflected) signals and multiple
sources of AE activity can cause large errors.
Location techniques are important for separating
clusters of AE activity for evaluation purposes
but the actual location of AE sources is
uncertain.
If AE data shows a tank has damage, plan to